81 515/121 ED 1/8 — ZDE3K* are direct operated pressure reducing valves, with electric proportional control, with ISO 4401-03 mounting surface. — They are compliant with ATEX, IECEx, INMETRO or PESO requirements and are suitable for use in potentially explosive atmospheres, for surface plants or mines. — A low temperature version (up to - 40 °C) is also available. — The valves are used to reduce pressure in the secondary circuit branches thus ensuring stability of controlled pressure in the event of variations of the flow rate through the valve. — ZDE3K* valves are supplied with a finishing…
File type: application/pdf
Referenced at:
21 SUCO Transmission Technology Electromagnetic Clutches and Brakes Customized Solutions Centrifugal Clutches and Brakes 2 1 Welcome to SUCO What you'll see on the following pages: SUCO PRESSOSTATS MÉCANIQUES TRANSMETTEURS DE PRESSION SUCO SUCO – A transmission technology specialist active on the global stage SUCO – A success story SUCO – Tradition and innovation SUCO worldwide – our international sales network Page 40 Page 3 Page 4 Page 6 SUCO CENTRIFUGAL CLUTCHES AND BRAKES Technical explanations F-Type – Self-increasing clutch S-Type – Pin-guided clutch with three fl yweights W-Type –…
File type: application/pdf
Referenced at:
Say hello to innovation! The new Ex-Valves 2.0 series brings solid enclosure coils, transforming safety measures in explosive environments. With compact design, flexible cable connections and impressive hydraulic power, these valves are a game-changer across industries. Let us explore the future of safety tech! NEW PRODUCT LINE OF EX-VALVES WITH A 2.0 COIL TECHNICAL ARTICLE T he fundamental difference in the new series of valves for potential explosive atmospheres lies in the method used to protect the electromagnetic coil. While the original series has the coil protected by potting compound…
File type: application/pdf
Referenced at:
16 150/125 ED 1/14 — VPPD pumps are variable displacement axial-piston pumps with variable swash plate, suitable for applications with open circuits and intermediate pressures. — They are available in three displacements of 15, 23 and 38 cm3/rev. — The pump flow rate is proportional to the rotation speed and to the angle of the swash plate, which can be continuously modulated. The maximum angle can be limited mechanically via a suitable regulating screw. — They are supplied with a SAE J744 2-holes pilot flange and cylindrical keyed shaft end, with BSPP threaded ports. — They are available with…
File type: application/pdf
Referenced at:
© 2024 Sun Hydraulics1 Rev. 2024-10-02a For detailed specifications visit www.sunhydraulics.com New Product Announcement! Model: FXDC Fixed-Orifice, Pressure Compensated Flow Control Valve http://www.sunhydraulics.com/ © 2024 Sun Hydraulics2 Rev. 2024-10-02a Cartridge Symbol and Dimensional Drawing FXDC Technical Features Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. • Customer must select a nominal flow setting range from the available options. Factory flow settings are…
File type: application/pdf
Referenced at:
© 2024 Sun Hydraulics1 Rev. 2024-10-02a For detailed specifications visit www.sunhydraulics.com New Product Announcement! Model: FXDC Fixed-Orifice, Pressure Compensated Flow Control Valve http://www.sunhydraulics.com/ © 2024 Sun Hydraulics2 Rev. 2024-10-02a Cartridge Symbol and Dimensional Drawing FXDC Technical Features Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. • Customer must select a nominal flow setting range from the available options. Factory flow settings are…
File type: application/pdf
Referenced at:
Product Manual X series Contents 1 General Instructions......................................................................... 4 1.1 About the manual............................................................................................................................................4 1.2 Intended use..................................................................................................................................................... 4 1.3…
File type: application/pdf
Referenced at:
81 506/121 ED 1/4 — PZME3 valves are three-port pressure reducing valves, pilot operated, with proportional control. They are designed in modular version with mounting interface in compliance with ISO 4401-03 standards. — These valves reduce pressure in the secondary branches of the circuit thus ensuring stability of controlled pressure in the event of variations in the flow rate through the valve. — The valve can be controlled directly by a current control supply unit or by an electronic control card, to maximize the valve performance (see point. 8). — The PZME3 valve is available in three…
File type: application/pdf
Referenced at:
Herderstraat 4 Industriepark Zuid B-8700 Tielt T. +32 (0)51 403 806 F. +32 (0)51 401 567 O.N. 0 405 233 534 info@vulkoprin.be www.vulkoprin.be EDELSTAHL GUMMI • STAINLESS STEEL RUBBER RT WK • RT WK PLATTE • TOP PLATE 166 8 8.1 8.1.1 0 1 /0 7 /2 0 1 7 ED ELSTAHL GUMMI 815/01/2014STAINLESS STEEL RUB BERRT WK 8.1RT WK8.1.1PLATTETO P PLATE Rad Polypropylen-Felge mit thermoplastischem Vollgummireifen 90° Shore A: Farbe grau, nicht kreidend, sehr leichtlaufend - mit 2RS Präzisionskugellager. Montiert in einem gepreßtem Edelstahlgehäuse mit zweireihigem Kugelkranz: abgedichtet, leicht schwenkbar -…
File type: application/pdf
Referenced at:
ACCUMULATOR 47 3 MOTOR HAND PUMP COUPLING BELL HOUSING PUMP 4 OFF HOLES Ø11 370 470 320 375 25 LITRE RESEVOIR OIL LEVEL SWITCH LEVEL GAUGE BRAKE CONTROL CIRCUITS RETURN LINE FILTER 594 74 0 “MP” Electro Hydraulic Power Units DS3002 This data sheet describes the Modular Power (MP) Electro Hydraulic Power Units, which have been designed to provide an advanced and flexible means of brake control. The MP unit is particularly useful when the installation requires the operation and control of two or more independent brake circuits, dual braking, or where there is a special requirement for meeting a…
File type: application/pdf
Referenced at: