SUCO Pressure Monitoring Mechanical Pressure Switches Electronic Pressure Switches Pressure Transmitters Sensor Technology Welcome to SUCO What you‘ll see on the following pages: SUCO MECHANICAL PRESSURE SWITCHES ELECTRONIC PRESSURE SWITCHES PRESSURE TRANSMITTERS esi SENSOR TECHNOLOGY SUCO – A leading specialist in pressure monitoring SUCO – A success story SUCO – Prepared for the future General technical explanations Overview of mechanical pressure switches Special technical explanations Selection Matrix – Choose your mechanical pressure switch Product descriptions and order numbers Overview…
File type: application/pdf
Referenced at:
SD2E-A4/H3 3/4-16 UNF • Qmax 30 l/min (8 GPM) • pmax 350 bar (5100 PSI) 4 3 (P) 2 1(T) S1 S2 Změny vyhrazeny · SD2E-A4_H3_4097_4cz_02/2023 Strana 1 www.argo-hytos.com 4/3 elektromagneticky ovládaný vestavný šoupátkový rozváděč Čtyřcestný třípolohový šoupátkový rozváděč s připojovacím závitem 3/4-16 UNF ovládaný dvěma elektromagnety, určený pro vestavbu do standardní komory A4 (C-8-4) v bloku. Ventil řídí směr proudění kapaliny a tím směr pohybu spotřebiče, nebo jej zastavuje. Technické parametry Popis funkce Technická data Charakteristiky měřeno při ν = 32 mm2/s (156 SUS) Teplota oleje 80 °C…
File type: application/pdf
Referenced at:
SD6H-AY4 3/4-16 UNF • Qmax 30 l/min (8 GPM) • pmax 350 bar (5100 PSI) 3 4 2 1 Y 3 4 2 1 Y 3 4 2 1 Y 3 4 2 1 Y Y 3 2 1 4 Změny vyhrazeny · SD6H-AY4_4053_1cz_01/2024 www.argo-hytos.comStrana 1 3/2 vestavný hydraulicky ovládaný rozváděč Ventil je určen k rozvádění pracovní hydraulické kapaliny pomocí šoupátka, které se posouvá v ocelovém pouzdru působením tlaku kapaliny na čelní plochu (1). Tlak potřebný k přestavení šoupátka se nastavuje stlačením pružiny pomocí nastavovacího šroubu. Bodový přenos síly pružiny na čelní plochu šoupátka pomocí kalené kuličky eliminuje působení radiálních sil a…
File type: application/pdf
Referenced at:
11 102/123 ED 1/14 GPA* EXTERNAL GEAR PUMPS SERIES 10 HYDRAULIC SYMBOL OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS PUMP GPA1 GPA2 GPA3 Displacement range cm3/rev 1 ÷ 7.5 4.5 ÷ 31.7 22 ÷ 61 Continuous operating pressure (NOTE) bar up to 260 up to 260 up to 250 Max rotation speed (NOTE) rpm 4000 4000 3000 Rotation direction clockwise or anticlockwise Loads on the shaft radial and axial load are not allowed Max torque applicable to the shaft see point 11.1 Hydraulic connections european flanged or BSPP threaded Type of mounting 4-holes flange - rectangular type Mass kg 1.3 ÷ 1.9 3.3 ÷ 4.6 5.8 ÷…
File type: application/pdf
Referenced at:
Tube Connectors Assembly Tools and Devices Catalogue 2 STAUFF Connect Please note: Unless otherwise stated, all data and figures in this product catalogue are approximate values and are only valid as references, which are not binding (also in respect to any third parties’ rights of protection) and thus do not release the customer / user from checking and testing the suitability of the products for the foreseen purposes. Therefore, data and figures can only be used in a limited sense for construction purposes. The application of the products is beyond the control possibilities of the…
File type: application/pdf
Referenced at:
Tube Connectors Assembly Tools and Devices Catalogue 2 STAUFF Connect Please note: Unless otherwise stated, all data and figures in this product catalogue are approximate values and are only valid as references, which are not binding (also in respect to any third parties’ rights of protection) and thus do not release the customer / user from checking and testing the suitability of the products for the foreseen purposes. Therefore, data and figures can only be used in a limited sense for construction purposes. The application of the products is beyond the control possibilities of the…
File type: application/pdf
Referenced at:
0 15 20 25 30 100 150 50 300 200 250 5 01 (5.3) (6.6)(1.3) (4.5)(2.6) (7.9) (1450) (730) (2180) (2900) (3630) (4350) 400 350(5080) (5800) 1 2 0 15 20 25 30 10 15 5 30 20 25 5 10 3 2 4 1 (1.3) (145) (73) (218) (290) (363) (435) (2.6) (4.5) (5.3) (6.6) (7.9) 2 4 3 1 2 4 3 1S1 S2S1 S2 SD2E-A4/H3 3/4-16 UNF • Qmax 30 l/min (8 GPM) • pmax 350 bar (5100 PSI) 4 3 (P) 2 1(T) S1 S2 Změny vyhrazeny · SD2E-A4_H3_4097_1cz_03/2022 Strana 1 www.argo-hytos.com 4/3 elektromagneticky ovládaný vestavný šoupátkový rozváděč Čtyřcestný třípolohový šoupátkový rozváděč s připojovacím závitem 3/4-16 UNF ovládaný…
File type: application/pdf
Referenced at:
SR4E2-C2 1 1/16-12 UN • Qmax 180 l/min (48 GPM) • pmax 350 bar (5100 PSI) /pmax p minP T p1 p2 Symbol Změny vyhrazeny · SR4E2-C2_5078_1cz_10/2023 Strana 1 www.argo-hytos.com Tlakový přepouštěcí ventil, nepřímo řízený, s přepínáním hodnot tlaku elektromagnetem Technické parametry Popis funkce Technická data Charakteristiky měřeno při ν = 32 mm2/s (156 SUS) Připojovací závit / komora 1 1/16-12 UN-2A / C2 (VC12-2) Maximální průtok l/min (GPM) 180 (47.6) Max. provozní tlak bar (PSI) 350 (5080) Max. tlak v kanálu T bar (PSI) 100 (1450) Min. nastavitelný tlak bar (PSI) 2,5 (36.3) Rozsah provozní…
File type: application/pdf
Referenced at:
IUM - WORKING INSTRUCTIONS AND MAINTENANCE - ATEX MANUAL CONTENTS General Information ......................................................... 2 Safety Warnings Product operation .............................................................. 2 Prevalent use .................................................................... 2 Transport .......................................................................... 2 Long-term storage ............................................................. 2 Environmental management ............................................. 2 Product Layout…
File type: application/pdf
Referenced at:
14 101/318 ED 1/10 RV1D VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTER SERIES 10 OPERATING PRINCIPLE — The RV1D pumps are variable displacement vane pumps with mechanical pressure compensator. — The pressure compensator keeps the cam ring of the pumping group in the eccentric position with use of an adjustable load spring. When the delivery pressure equals the pressure corresponding to the spring setting, the cam ring is moved toward the center instantaneously, adjusting the flow rate to the values required by the plant. — Energy consumption is reduced and adequate in every…