S700 servo inverters for KOLLMORGEN
The S700 is a digital actuator with extended functionality that is ideal for complex control tasks. It includes an integrated Ethernet connection for use with EtherCAT® and SynqNet ™, and an optional MMC memory card allows easy backup of parameter records and firmware in the field. The safe torque off function is standard and additional safety features can be added. Single cable feedback with both SFD3 and Hiperface DSL is also supported.
Features:
- Tested for CE, UL, TÜV
- Operation directly from grounded 110 to 480 VAC, 1 or 3-phase lines, 50 to 60 Hz
- Models with a maximum continuous output current of 1.5 to 72 A RMS / phase
- Safe Torque Off (STO) function on the vehicle
- Security expansion cards available with SIL2 or SIL3 security features such as SDI, SLS, SS1, SS2, SBC and more
- On-board communication between EtherCAT® and CANopen
- Support for legacy buses including PROFINET, DeviceNet, PROFIBUS DP, SERCOS II and RS232
- Feedback of one SFD3 and Hiperface DSL cable
- MMC memory card slot for backing up and copying parameters and firmware
- Optimized compiler interface
- Automatic tuning
- Suppression of teeth
- The fastest feedback evaluation on the market
Advantages:
- High speed current, speed and position control lead to higher machine cycle frequencies
- SIL2 / SIL3 safety features increase machine availability
- The IEC 61131 macro programming language inside allows for flexibility of movement
- Multiple interface and feedback features provide compatibility with all standard controllers and feedback systems, reducing the need to store multiple types of disks
- Integrated EMC filters and integrated power supply and braking resistor enable smaller switchboards
- Memory card for updating parameters and firmware, auto-tuning functions and connectors for all connections allow faster setup
Rated data | DIM | S701 | S703 | S706 | S712 | S7120P | S724 | S7240P | S748 | S772 |
Rated line voltage | V~ | 3 x 208V-10% … 3 x 480V+10%, 50/60 Hz | ||||||||
Rated line power for S1 operation | kVA | 1,1 | 2,2 | 4,5 | 9 | 9 | 18 | 18 | 35 | 50 |
Auxiliary supply | V= | | | 24 | | | ||||
Rated DC-link voltage | V= | | | 290-675 | | | ||||
Rated output current (RMS value) | ||||||||||
-At 3 x 208 V | A RMS | 2,5 | 5 | 6 | 12 | 12 | 24 | 24 | 48 | 72 |
- At 3 x 230 V | A RMS | 2 | 4 | 6 | 12 | 12 | 24 | 24 | 48 | 72 |
- At 3 x 400 V | A RMS | 1,5 | 3 | 6 | 12 | 12 | 24 | 24 | 48 | 72 |
-At 3 x 480 V | A RMS | 1,5 | 3 | 6 | 12 | 12 | 24 | 24 | 48 | 70 |
peak output current (RMS value) | A RMS | 4,5 | 9 | 18 | 24 | 30 | 48 | 72 | 96 | 140 |
Rated data | DIM | S701 | S703 | S706 | S712 | S7120P | S724 | S7240P | S748 | S772 |
(H) Height incl. Fan | mm | 345 | 348 | 385 | ||||||
(W) Width | mm | 70 | 100 | 190 | ||||||
(D) Depth incl. Connector | mm | 243 | |