ARGO-HYTOS: Design change of the vent screw
The manufacturer of the hydraulic components informs about the design change of the built-in proportional pressure valves (SR4P2-B2, SP4P2-B3 and their control valve SR1P2-A2).
The design of the end part of the control system with the vent screw has been changed and the total length of the valve is shortened by 20 mm. At the same time, the possibility of setting the initial pressure with the solenoid switched off disappears. This change only applies to valves with a positive characteristic (pressure as a function of the control signal).
Valves with a negative characteristic (with an "N" in the order key) remain unchanged.